Model | ENH-115S-O-100 | ENH-115S-O-200 |
Type | Outer lateral-mount type | |
Cooling scheme | Super thermal conduction pipe (Heat pipe) type Totally non=freon (Using pure water) | |
Rated capability | 15/18 W/K(50/60Hz) | |
Power supply(50/60Hz) | 1 phase 100VAC±10% | 1 phase 200VAC±10% |
Outer dimensions(mm) | H680×W177×D45 | |
Current consumption(A)(MAX) | 0.42/0.36 | 0.42/0.36 |
Starting current(A)(MAX) | 0.6/0.52 | 0.6/0.52 |
Power consumption(MAX)(W) | 30/28 | |
Allowable ambient temperature(ºC) | 60 or less | |
Allowable ambient humidity(%) | 10 to 85 (No condensation) | |
Operation control scheme | Continuous air cooling | |
Number of fans | 2 | |
Weight(kg) | 4 | |
Paint color | Munsell 5Y7/1 Equivalent color of light beige |
Model | ENH-115L-O-100 | ENH-115L-O-200 |
Type | Outer lateral-mount type | |
Cooling scheme | Super thermal conduction pipe (Heat pipe) type Totally non=freon (Using pure water) | |
Rated capability | 15/18 W/K(50/60Hz) | |
Power supply(50/60Hz) | 1 phase 100VAC±10% | 1 phase 200VAC±10% |
Outer dimensions(mm) | H426×W177×D70 | |
Current consumption(A)(MAX) | 0.42/0.36 | 0.22/0.18 |
Starting current(A)(MAX) | 0.6/0.52 | 0.32/0.3 |
Power consumption(MAX)(W) | 30/28 | |
Allowable ambient temperature(ºC) | 60 or less | |
Allowable ambient humidity(%) | 10 to 85 (No condensation) | |
Operation control scheme | Continuous air cooling | |
Number of fans | 2 | |
Weight(kg) | 4 | |
Paint color | Munsell 5Y7/1 Equivalent color of light beige |
Model | ENH-130L-O-100 | ENH-130L-O-200 |
Type | Outer lateral-mount type | |
Cooling scheme | Super thermal conduction pipe (Heat pipe) type Totally non=freon (Using pure water) | |
Rated capability | 30/35W/K(50/60Hz) | |
Power supply(50/60Hz) | 1 phase 100VAC±10% | 1 phase 200VAC±10% |
Outer dimensions(mm) | H710×W198×D100 | |
Current consumption(A)(MAX) | 1.2/1.0 | 0.6/0.52 |
Starting current(A)(MAX) | 2.6/2.2 | 1.4/1.3 |
Power consumption(MAX)(W) | 86/80 | |
Allowable ambient temperature(ºC) | 60 or less | |
Allowable ambient humidity(%) | 10 to 85 (No condensation) | |
Operation control scheme | Continuous air cooling | |
Number of fans | 2 | |
Weight(kg) | 6 | |
Paint color | Munsell 5Y7/1 Equivalent color of light beige |
Model | ENH-165L-O-100 | ENH-165L-O-200 |
Type | Outer lateral-mount type | |
Cooling scheme | Super thermal conduction pipe (Heat pipe) type Totally non=freon (Using pure water) | |
Cooling capacity(W) | 65/78W/K(50/60Hz) | |
Power supply(50/60Hz) | 1 phase 100VAC±10% | 1 phase 200VAC±10% |
Outer dimensions(mm) | H655×W388×D90 | |
Current consumption(A)(MAX) | 2.4/2.0 | 1.2/1.0 |
Starting current(A)(MAX) | 5.2/4.4 | 2.8/2.6 |
Power consumption(MAX)(W) | 160/140 | |
Allowable ambient temperature(ºC) | 60 or less | |
Allowable ambient humidity(%) | 10 to 85 (No condensation) | |
Operation control scheme | Continuous air cooling | |
Number of fans | 4 | |
Weight(kg) | 13 | |
Paint color | Munsell 5Y7/1 Equivalent color of light beige |