Cabinet & Component

APISTE Panel Cooling Unit – Outdoor Lateral-mount Type
APISTE Panel Cooling Unit – Outdoor Lateral-mount […]

APISTE Panel Cooling Unit – Outdoor Lateral-mount Type

ENC-A510HD/A520HD

ModelENC-A510HDENC-A520HD
TypeOutdoors lateral-mount type
Cooling schemeCompressor
Cooling capacity (W)300/380(50/60Hz)
Power supply (50/60Hz)1 phase 100VAC±10%1 phase 200VAC±10%
Current consumption (A)(MAX)3.9/3.82.0/1.7
Starting current (A)7.4/7.74.0/4.2
Power consumption (W)(MAX)330/370330/320
Allowable ambient temperature (ºC)0 to 50
Allowable ambient humidity (%)10 to 85 (No condensation)
Operation control schemeMicrocomputer-based automatic control
RefrigerantR-134a (A kind of freon that is not prohibited)
Temperature setting range (ºC)25 to 45
Number of fans1
Outer dimensions (mm)H:300×W:115×D:530
Weight(kg)15

ENC-AR510HD/AR520HD

ModelENC-AR510HDENC-AR520HD
TypeOutdoors lateral-mount type
Cooling schemeCompressor
Cooling capacity (W)450/550(50/60Hz)
Power supply (50/60Hz)1 phase 100VAC±10%1 phase 200VAC±10%
Current consumption (A)(MAX)3.9/4.22.1/1.9
Starting current (A)7.4/7.74.9/4.4
Power consumption (W)(MAX)365/410365/360
Allowable ambient temperature (ºC)-5 to 50
Allowable ambient humidity (%)10 to 85 (No condensation)
Operation control schemeMicrocomputer-based automatic control
RefrigerantR-134a (A kind of freon that is not prohibited)
Temperature setting range (ºC)25 to 45
Number of fans2
Outer dimensions (mm)H:450×W:350×D:200
Weight(kg)17

ENC-A1010HD/A1020HD

ModelENC-A1010HDENC-A1020HD
TypeOutdoors lateral-mount type
Cooling schemeCompressor
Cooling capacity (W)900/1000 (50/60Hz)
Power supply (50/60Hz)1 phase 100VAC±10%1 phase 200VAC±10%
Current consumption (A)(MAX)6.5/6.33.1/3.0
Starting current (A)15.6/14.77.5/7.1
Power consumption (W)(MAX)595/615570/590
Allowable ambient temperature (ºC)-5 to 50
Allowable ambient humidity (%)10 to 85 (No condensation)
Operation control schemeMicrocomputer-based automatic control
RefrigerantR-134a
Temperature setting range (ºC)25 to 45
Number of fans2
OutputOutput of operation & alarm(250V 2A)
DisplayLED Temperature/Error Run
Noise immunityLevel 4 in the fast transient/Burst immunity test
Noise (dB)Approx. 64/66
Vibration resistanceVibration frequency : 5Hz ; a double amplitude of 20mm
Outer dimensions (mm)H730×W300×D280
Weight(kg)26

ENC-AR1010HD/AR1020HD

ModelENC-AR1010HDENC-AR1020HD
TypeOutdoors lateral-mount type
Cooling schemeCompressor
Cooling capacity (W)900/1000 (50/60Hz)
Power supply (50/60Hz)1 phase 100VAC±10%1 phase 200VAC±10%
Current consumption (A)(MAX)6.5/6.33.1/3.0
Starting current (A)15.6/14.77.5/7.1
Power consumption (W)(MAX)595/615570/590
Allowable ambient temperature (ºC)-5 to 50
Allowable ambient humidity (%)10 to 85 (No condensation)
Operation control schemeMicrocomputer-based automatic control
RefrigerantR-134a
Temperature setting range (ºC)25 to 45
Number of fans2
OutputOutput of operation & alarm(250V 2A)
DisplayLED Temperature/Error Run
Noise immunityLevel 4 in the fast transient/Burst immunity test
Noise (dB)Approx. 64/66
Vibration resistanceVibration frequency : 5Hz ; a double amplitude of 20mm
Outer dimensions (mm)H730×W300×D280
Weight(kg)26

ENC-A1610HD/A1620HD

ModelENC-A1610HDENC-A1620HD
TypeOutdoors lateral-mount type
Cooling schemeCompressor
Cooling capacity (W)1450/1600 (50/60Hz)
Power supply (50/60Hz)1 phase 100VAC±10%1 phase 200VAC±10%
Current consumption (A)(MAX)8.5/8.84.3/4.5
Starting current (A)22.3/20.513/12
Power consumption (W)(MAX)740/830780/840
Allowable ambient temperature (ºC)-5 to 50
Allowable ambient humidity (%)10 to 85 (No condensation)
Operation control schemeMicrocomputer-based automatic control
RefrigerantR-407c (A kind of freon that is not prohibited)
Temperature setting range (ºC)25 to 45
Number of fans4
Outer dimensions (mm)H:1000×W:400×D:260
Weight(kg)42

ENC-AR1610HD/AR1620HD

ModelENC-AR1610HDENC-AR1620HD
TypeOutdoors lateral-mount type
Cooling schemeCompressor
Cooling capacity (W)1450/1600 (50/60Hz)
Power supply (50/60Hz)1 phase 100VAC±10%1 phase 200VAC±10%
Current consumption (A)(MAX)8.5/8.84.3/4.5
Starting current (A)22.3/20.513/12
Power consumption (W)(MAX)740/830780/840
Allowable ambient temperature (ºC)-5 to 55
Allowable ambient humidity (%)10 to 85 (No condensation)
Operation control schemeMicrocomputer-based automatic control
RefrigerantR-407c (A kind of freon that is not prohibited)
Temperature setting range (ºC)25 to 45
Number of fans4
Outer dimensions (mm)H:1000×W:400×D:260
Weight(kg)42

ENC-A2900HD

ModelENC-A2900HD
TypeOutdoors lateral-mount type
Cooling schemeCompressor
Cooling capacity (W)2600/2900(50/60Hz)
Power supply (50/60Hz)1 phase 200VAC±10%
Current consumption (A)(MAX)9.3/9.4
Starting current (A)33/30
Power consumption (W)(MAX)1650/1850
Allowable ambient temperature (ºC)-5 to 55
Allowable ambient humidity (%)10 to 85 (No condensation)
Operation control schemeMicrocomputer-based automatic contorl
RefrigerantR-134a (A kind of freon that is not prohibited)
Temperature setting range (ºC)25 to 45
Number of fans6
Outer dimensions (mm)H:1380×W:450×D:295
Weight(kg)60

ENC-AR2900HD

ModelENC-AR2900HD
TypeOutdoors lateral-mount type
Cooling schemeCompressor
Cooling capacity (W)2600/2900(50/60Hz)
Power supply (50/60Hz)1 phase 200VAC±10%
Current consumption (A)(MAX)9.3/9.4
Starting current (A)33/30
Power consumption (W)(MAX)1650/1850
Allowable ambient temperature (ºC)-5 to 55
Allowable ambient humidity (%)10 to 85 (No condensation)
Operation control schemeMicrocomputer-based automatic contorl
RefrigerantR-134a (A kind of freon that is not prohibited)
Temperature setting range (ºC)25 to 45
Number of fans6
Outer dimensions (mm)H:1380×W:450×D:295
Weight(kg)60