Cabinet & Component

APISTE Air Conditioner
Apiste provide the products “Air Conditioner̶ […]

Apiste provide the products “Air Conditioner” for control box, control panel, server rack, heat exchanger and precision air conditioning system with a wide range of type such as Inner Lateral-Mount Type, Outer Lateral-Mount Type, Ceiling-Mount Type, Power Supply for Oversea Type, Outdoors Heat Exchanger, Temperature Adjustment Unit and Panel Heater

Control Panel Cooling Unit

Why you need the Control Panel Cooling Unit? Normally in your Control Panel Unit you have a lot of electrical components like Transformer, Power supply, Inverter, Servo Amplifier etc. this kind of electrical components will be generated a “Heat” in your control panel. This kind of heat make your Electronics Controls Devices like a PLC, Touch Panel, Motion Controller and other Controller are broken down, Error and your controller will have a short life time.

What is the Control Panel Cooling Unit?

Cooling : Reducing the temperature in your Control Panel.
Benefit : No Error, Machine Brake Down and give your Controller have a Long life time.
Dehumidity : Reducing the Humidity in your Control Panel.
Benefit : low humidity make your controller have a long lift time.
Dust Prevention : completely insulate by internal air circulation inside only.
Benefit : No Dust, Oil Mist or Particle come inside your control panel.

Mount Type ENC Series

Ceiling-Mount Type

Apiste ENC Series Model Lineup

  • ENC-A310EX/A320EX
  • ENC-AR310EX/AR320EX
  • ENC-A510EX/A520EX
  • ENC-AR510EX/AR520EX
  • ENC-A710EX/A720EX
  • ENC-AR710EX/AR720EX
  • ENC-A1110EX/A1120EX
  • ENC-AR1110EX/AR1120EX
  • ENC-A1652EX
  • ENC-AR1652EX
  • ENC-A2200EX
  • ENC-AR2200EX
  • ENC-A2900EX
  • ENC-AR2900EX
  • ENC-A3500EX

Ceiling-mount Type — EX Series –

Best suited for coupled control panels or a control panel facing an aisle or limited the space.

The ceiling-mount type is a perfect choice when it is difficult to mount the system on the side wall of the control panel, such as when several control panels are installed side by side, when a control panel faces an aisle, or when a control panel is surrounded with devices. The system can be mounted neatly

Non-drain Lateral-mount Type

  • ENC-A310L/A320L
  • ENC-AR310L/AR320L
  • ENC-351/352WL
  • ENC-A451S/A452S
  • ENC-AR451S/AR452S
  • ENC-A610L/A620L
  • ENC-AR610L/AR620L
  • ENC-A1110L/A1120L
  • ENC-AR1110L/AR1120L
  • ENC-A1651L/A1652L
  • ENC-AR1651L/AR1652L
  • ENC-A2200L
  • ENC-AR2200L
  • ENC-A2900L
  • ENC-AR2900L
  • ENC-A5500L
  • ENC-A1020L-DF
  • ENC-AR2200L-DF

Lateral-mount type — L Series –

The system for standard mounting that can be mounted and maintained easily

The system can be easily mounted on the side wall of the control panel. Since it is positioned at eye level, maintenance is also easy. Another advantage is that it is easy to discharge drain water.

Self-diagnostic function with alarm output & Digital display

Reliable “inside temperature display”

Apiste’s control panel coolers feature various display functions.
The “inside temperature display”, in particular, is a function that we proud of. It shows the temperature inside of the control panel.
The real time indication of the inside temperature not only is useful to prevent improper settings or to know the current cooling condition, but also provides great peace of mind as a facility to monitor the inside of the control panel.

“High-intensity LED” for high visibility from a distance
The inside temperature is shown with a digital display using a high-intensity LED display.
Although the control panel is normally closed to control temperature, humidity, and dust, you can easily check the conditions of the inside at a glance even from distance.
The easy-to-see red LED display illuminates as soon as the system is powered on.

Problems that are displayed

  • Stoppage or deterioration of the circulating fan
  • Water leak from the primary drain pan
  • Clogged filter, Abnormally high temperature
  • Disconnection of the thermistor

Display of various problems and alarm outputs
Display of various problems is useful to prevent accidents and make daily maintenance easier.
The system features a protection circuit with double or triple redundancy. When any abnormality is found, it issues an alarm output, or, in specific cases, issues an emergency stop.
This is the result of our relentless pursuit of safety.

Non-drain Lateral-mount Type

  • ENC-AR510LE/AR520LE
  • ENC-AR810LE/AR820LE
  • ENC-AR1310LE
  • ENC-AR1320LE
  • ENC-AR2400LE

400V Lateral-mount Type

  • ENC-AR2240L
  • ENC-AR2940L
  • ENC-2240L-DF
  • ENC-2940L-DF

Overseas Model

  • ENC-A520EX-CE
  • ENC-A1120EX-CE
  • ENC-A1652EX-CE
  • ENC-A2900EX-CE
  • ENC-351WL-CE
  • ENC-AR452L-CE
  • ENC-620L-CE
  • ENC-1020L-CE
  • ENC-2200L-CE
  • ENC-520EX-UL
  • ENC-720EX-UL
  • ENC-1020EX-UL
  • ENC-1652EX-UL
  • ENC-2200EX-UL
  • ENC-2900EX-UL
  • ENC-452L-UL
  • ENC-620L-UL
  • ENC-1020L-UL
  • ENC-1652L-UL
  • ENC-2200L-UL
  • ENC-2900L-UL
  • ENC-823L

Inner Lateral-mount Type

  • ENH-105L-100/200
  • ENH-110L-100/200
  • ENH-115S-100/200
  • ENH-115L-100/200
  • ENH-130L-100/200
  • ENH-165L-100/200

ENH Series Oversea Power Supply Type

  • ENH-110L Series
  • ENH-115L Series
  • ENH-130L Series
  • ENH-165L Series

Inner Lateral-Mount Type

  • ENH-P110L-100/200
  • ENH-P120L-100/200
  • ENH-P140L-100/200

Outer Lateral-Mount Type

  • ENH-115S-O-100/200
  • ENH-115L-O-100/200
  • ENH-130L-O-100/200
  • ENH-165L-O-100/200